Sub..end sub
The sub..end sub control statement defines a subroutine which can be called upon from a call statement.
Syntax:
Sub name [ ( paramlist )] statements end sub
Arguments are copied into the subroutine and, if the corresponding actual parameter in the call statement is a variable name, copied back out again upon exiting the subroutine.
If a subroutine has more formal parameters than actual parameters passed by a call statement, the extra parameters will be initialized to NULL and can be used as local variables within the subroutine.
Since the sub statement is a control statement and as such is ended with either a semicolon or end-of-line, each of its two clauses (sub and end sub) must not cross a line boundary.
Arguments:
Argument | Description |
---|---|
name | The name of the subroutine. |
paramlist | A comma separated list of variable names for the formal parameters of the subroutine. These can be used as any variable inside the subroutine. |
statements | Any group of one or more QlikView script statements. |
Example 1:
Sub INCR (I,J)
I = I + 1
Exit Sub when I < 10
J = J + 1
End Sub
Call INCR (X,Y)
Example 2: - parameter transfer
Sub ParTrans (A,B,C)
A=A+1
B=B+1
C=C+1
End Sub
A=1
X=1
C=1
Call ParTrans (A, (X+1)*2)
The result of the above will be that locally, inside the subroutine, A will be initialized to 1, B will be initialized to 4 and C will be initialized to NULL.
When exiting the subroutine, the global variable A will get 2 as value (copied back from subroutine). The second actual parameter “(X+1)*2” will not be copied back since it is not a variable. Finally, the global variable C will not be affected by the subroutine call.